Fundamentals of COM 266 IP 266
Auxiliary screen form for Mode Select
Different modes require different entries in the "TEST" form's input fields.
Table 6-4 shows the allocation of input fields to modes.
Table 6-4. Input Fields for Modes 1 to 19
Entry required for this mode
Mode 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Program •••
Distance/Targe
t
•• ••
Override ••• ••
Selecting a mode
If you do not know the number of the mode you want to select, press <F7>
(HELP) to screen a mode list.
Figure 6-25. Table of Operating Modes for Testing
TEST SIMATIC S5 / COM266
INCREMENTAL_ABSOLUTE START DEVICE: IP266 BLOCK: DB
F2 F3 F4 F5 F7 F8
EXIT
F6
TRANSFER
F1
Operating modes for testing
1 Jog speed 1 11 Teach-In off
2 Jog speed 2 12 Zero offset absolute
3 Jog open loop 13 Zero offset relative
4 Follow-up mode 14 Clear zero offset
5 Reference point approach 15 Tool offset
6 Incremental absolute 16 Tool offset off
7 Incremental relative 17 Delete error
8 Automatic 18 Drift compensation
9 Autom. single statement 19 Drift compensation off
10 Teach-In on
Enter number of operating mode 5
6-66