IP 266 Machine Data, Modes and Traversing Programs
Example: The drive is at the absolute position + 150 mm. Zero offsets of 300 mm,
- 200 mm, - 150 mm and 50 mm are to be carried out in succession.
Select mode 13.
Enter the value for the offset, including the sign.
Start the mode with the "Forward" or "Reverse" function. The
function specifies the direction of the offset.
Repeat the sequence for each of the zero offsets.
The coordinate system must respond as shown in Figure 5-25.
Note:
If you want to start the mode with the "Reverse" function, you must invert the
sign when you enter the offset value.
Figure 5-25. Relative Zero Offset with Different Values
s
0
ZO 300 forw.
ZO -200 forw.
ZO -150 forw.
s
ZO -50 reverse
0
0
0
0
-50
-50
150
150
300
300
50
50
200
200 350
-350 -300 -150
-150 -100
Actual value