IP 266 Machine Data, Modes and Traversing Programs
Read distance to go (mode 73)
Read distance to go
Mode
Start
FunctionParameters
Select this mode when you want to initiate additional actions in your STEP 5 pro-
gram prior to termination of an IP 266 job (e. g. 20 mm before the target
position).
5.3.22 Synchronize IP (Mode 99)
Synchronize IP
Mode
Start
FunctionParameters
This mode must be selected when the IP 266 is put into operation, as it synchro-
nizes communication between the PLC and the IP 266.
This mode must be started after every PLC cold (power off/power on) or warm
(STOP RUN) restart and after every IP 266 reset. If this mode is not started, it
will not be possible to invoke any other mode.
As in the case of the Information modes, this mode does not return information
to the STEP 5 program.
Note:
This mode is not needed to work with COM 266.
EWA 4NEB 812 6057-02
5-67