Troubleshooting IP 266
Recovery Procedures
Wrong resolution
The resolution must lie in the range from 0.1 to 99.9, and is computed as
follows:
The unit of resolution depends on the parameter specification. You must
take into account that the dimensional unit of resolution is always
Travel per encoder revolution
Pulses per encoder revolution
A =
Error Code
F02
F03 Wrong maximum speed
The speed specification must lie in the range from 1 to 65000.
F04 Wrong JOG/INC speed
All speeds must be 1 and of the specified maximum speed.
F05 Wrong reference speed
For the IP 266, reference speed 1 must be 1 and the specified
maximum speed. Reference speed 2 must also be > 1, but reference
speed 1.
1 reference speed 2 reference speed 1 maximum speed.
Basic unit/1000
Pulses
Basic unit Resolution
mm
0.1 inch
deg
µm
0.0001 inch
0.001 deg
Cross-
reference
Section 5.1.2
Section 5.1.4
Section 5.1.4
Section 5.1.4
10-4
EWA 4NEB 812 6057-02