IP 266 Machine Data, Modes and Traversing Programs
G70: Dimensions in 0.1 inch
G71: Dimensions in mm
The IP 266 positioning module always interprets traversing programs in the
dimension specified in the machine data.
Table 5-22. Preselecting Dimensions
Dimensions in the unit Invoke via function
G70
G71
G70 and G71 ineffective
[0.1 inch ]
[
mm]
[
degrees]
Functions G70 and G71 can be used to change the dependence of dimensions
on the specification made in the machine data.
G functions cannot be used to implement this options for a rotary axis that was
initialized in [deg] in the machine data.
Note:
G70: Dimensions in 0.1 inch
When the G70 function is invoked, all subsequent distances are interpreted in
units of 0.1 inches and all subsequent speeds in 0.1 inches/min.
G71: Dimensions in mm
When G71 is invoked, all subsequent distances are interpreted in mm and all
subsequent speeds in mm/min.