IP 266 Machine Data, Modes and Traversing Programs
5.3.16 Disable Tool Offset (TO) (Mode 16)
Disable tool offset
Mode
Start
FunctionParameters
This mode resets all tool offsets that were set via
mode 15 or
G functions in the traversing programs
Mode 16 cancels all tool offsets, i. e. you cannot use this mode to revoke the tool
offset that was set via mode 15 while retaining the tool offset that was set via
G functions.
5.3.17 Acknowledge Error (Mode 17)
Acknowledge error
Mode
Start
FunctionParameters
Errors occurring during operation or during IP 266 start-up may have a number of
different causes, such as
operator input error
external event (such as tripping of a limit switch)
incomplete installation (e. g. machine data not complete)
errors in machine data
Mode 17 is used to acknowledge an error.
Aside from mode 17, you can acknowledge an error only by starting another
mode.
You cannot acknowledge an error by invoking an info (i. e. monitoring) mode.
EWA 4NEB 812 6057-02
5-61