STEP 5 Programming IP 266
FB 2: Jog 2 with override specification
When the mode number has been entered into QB 64, input 3.6 is scanned. Select
an override of 50 % or 100 %, depending on the selector switch setting. This
value is entered in QB 67.
Enter mode
number into
QB 64
END
Select 100 %
override and enter
into QB 67
Select 50 %
override and enter
into QB 67
I 3.6
set?
yes
START
FB 2 - NAME:MO2
Select mode
LKB2
TQB64
Override set via selector switch:
A I 3.6 50% / 100%
JC =M100
L KB 50 50%
TQB67
BEU
M100 L KB 100 100%
TQB67
BE