
IP 266 Fundamentals of COM 266
Data area:
"Type" column: I = input field, O = output field
TypeField name
Module:
Meas.System:
Axis type:
Maximum speed
O
Description
These fields are the same as those in the data area on page 1.
I
Jog speed 1 fwd: I Speed for forward jogging in "Jog 1" mode.
Jog speed 1 rev: I Speed for reverse jogging in "Jog 1" mode.
Jog speed 2 fwd: I Speed for forward jogging in "Jog 2" mode.
Jog speed 2 rev: I Speed for reverse jogging in "Jog 2" mode.
Incremental
speed:
I Speed for modes 6 and 7.
This value defines the speed at which the axis is positioned when the
power section's applied voltage is 10 V. All subsequent speed specifi-
cations must be lower than or equal to the maximum speed.
Function key menu:
The function key menu is identical to that on page 2 of the "INPUT
MACHINEDATA" form.
And what now?
Enter all speed values in the appropriate fields.
Press <F1> to screen page 7 of "INPUT MACHINEDATA".
EWA 4NEB 812 6057-02
6-33
Comentarios a estos manuales