Siemens IP-Module Manual Pagina 129

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 360
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 128
IP 266 Machine Data, Modes and Traversing Programs
The direction of the tool offset is determined by
the sign of the offset value and
the Start function ("Forward" or "Reverse")
Table 5-16. Coordinate Changes Produced by a Tool Offset
Sign of the
value
Start function Coordinates become
Forward
Forward
Reverse
Reverse
Positive
Negative
Negative
Positive
more positive
more negative
more negative
more positive
Following a tool offset, the position of the new tool tip is always displayed as
actual position. The tool offset is taken into account when a target position is
specified.
The range of the software limit switches is recomputed following a tool offset.
Use the following formulas as basis for specification of a tool offset:
In a negative direction:
- Tool offset 32767.999 - |Software end limit switch|
In a positive direction:
Tool offset 32767.999 - |Software start limit switch|
The IP 266 does not execute a tool offset outside the permissible range limits.