Machine Data, Modes and Traversing Programs IP 266
5.3.11 Disable Teach-In (Mode 11)
Disable teach-in
Mode
Start
FunctionParameters
This mode disables teach-in (mode 10).
Prerequisites:
Mandatory: Mode 10 was started.
Recommended: The creation of positioning blocks in mode 10.
End block Nnn M02 is entered in the machining program. nn is the block number.
The value of Nnn depends on the current length of the traversing program.
5.3.12 Absolute Zero Offset (ZO) (Mode 12)
Absolute coordinateAbsolute zero offset
Mode
Start
FunctionParameters
A ZO is used to assign new coordinates to a drive system. A ZO transforms all coor-
dinates for
the reference point and
the software limit switches
and checks them for validity. No reference point need be set when this mode is
invoked.
An "Absolute zero offset" assigns the value of the "Absolute coordinate" param-
eter to the actual value. This value is referred to in the following as ZO, or zero
offset.
Actval
new
= ZO
The zero point is offset by the value
ZO - Actval
old
The "Invalid position specification" error message is displayed if the maximum
range is exceeded.
5-50
EWA 4NEB 812 6057-02