Machine Data, Modes and Traversing Programs IP 266
Example: Relative increment mode is to be invoked at starting positions A
(-10 mm) and B (60 mm).
Figure 5-21. Relative Target Specification
- 10
D
Reference pointReference point
A B
s/m
m
5040302010 0 60 70 80 90
100
- 20- 30- 40
C
Forward
You start mode 7 with the parameters
- Override 100%,
- Distance: +30 mm
and the "Forward" or "Reverse" function.
Based on the starting positions in Figure 5-21, the table below shows the re-
sulting values:
Table 5-10. Using the 'Forward' Function in Mode 7
Travel Starting position
(absolute)
Distance Target position
(absolute)
A C
B D
-10 mm
+60 mm
+30 mm
+30 mm
+20 mm
+90 mm
5-42
EWA 4NEB 812 6057-02