36
© EPCOS AG 2015
Please read Important notes on page 4 and Cautions and warnings on page 5.
Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5.
Light-duty types
2.5 kA / 2.5 A
l
ø 5.5 x 6 mm
Light-duty / High-voltage types
2 kA / 2 A
l
ø 5.5 × 6 mm
EM… EM1000X / EM2000X
ø5.5±0.2
ø0.8
6±0.2
Type
Ordering code
EM90X
B88069X
0190S102
EM230X
B88069X
0900S102
EM300X
B88069X
0800S102
EM350X
B88069X
0590S102
EM400X
B88069X
0200S102
EM1000X
B88069X
4651S102
EM2000X
B88069X
5600S102
Nom. DC spark-over voltage V
sdcN
90 230 300 350 400 1000 2000 V
Tolerance of V
sdcN
±20 ±20% –10/+15 ±20 ±20 ±20 ±20 %
Impulse spark-over voltage
@ 100 V/µs 99% of
measured values
< 400 < 650 < 700 < 800 < 800 < 1700 < 3400 V
@ 100 V/µs typical values < 330 < 600 < 600 < 700 < 750 < 1600 < 3200 V
@ 1 kV/µs 99% of
measured values
< 600 < 700 < 800 < 900 < 900 < 1900 < 4100 V
@ 1 kV/µs typical values < 530 < 650 < 700 < 800 < 850 < 1800 < 3800 V
Service life
10 operations 50 Hz, 1 s 2.5 2.5 2.5 2.5 2.5 2 1.5 A
3 operations 8/20 µs – – – – – 2 2 kA
10 operations 8/20 µs 2.5 2.5 2.5 2.5 2.5 – – kA
1 operation 10/350 µs 0.5 0.5 0.5 0.5 0.5 – – kA
300 operations 10/1000 µs 100 100 100 100 100
100 100 A
Insulation resistance > 1 > 1 > 1 > 1 > 1 > 1 > 1 GΩ
Capacitance @ 1 MHz < 1 < 1 < 1 < 1 < 1 < 1 < 1 pF
About packing see page 71.
2-Electrode Arresters
2-Elektroden-Ableiter