34
© EPCOS AG 2015
Please read Important notes on page 4 and Cautions and warnings on page 5.
Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5.
Light-duty types
2 kA / 2 A
l
4.5 × 3.2 × 2.7 mm
S30-…
2.7±0.3
4.5±0.3
0.5±0.1
5.9 max.
3.8 min.
Tin-plated
Type
Ordering code
S30-A75X
B88069X
1023T203
S30-A90X
B88069X
9231T203
S30-A150X
B88069X
6071T203
S30-A230XS
B88069X
9801T203
S30-A300XS
B88069X
6891T203
S30-A350X
B88069X
8361T203
S30-A420XS
B88069X
6311T203
S30-A500XS
B88069X
1873T203
Nom. DC spark-over voltage V
sdcN
75 90 150 230 300 350 420 500 V
Tolerance of V
sdcN
±30 ±30 ±30 ±30 ±30 ±25 ±25 ±20 %
Impulse spark-over voltage
@ 100 V/µs 99% of
measured values
< 400 < 500 < 500 < 500 < 580 < 750 < 650 < 950 V
@ 100 V/µs typical values < 350 < 400 < 400 < 400 < 500 < 700 < 550 < 800 V
@ 1 kV/µs 99% of
measured values
< 700 < 600 < 600 < 600 < 650 < 900 < 750 < 1050 V
@ 1 kV/µs typical values < 650 < 500 < 500 < 500 < 550 < 850 < 600 < 900 V
Service life
10 operations 8/20 µs 2 2 2 1 1 2 1 1 kA
100 operations 8/20 µs 100 100 100 100 100 100 100 100 A
10 operations 5/320 µs
1)
150 150 150 150 150 150 150 150 A
100 operations 10/1000 µs
10 10 10 10 10 10 10 10 A
Insulation resistance > 1 > 1 > 1 > 1 > 1 > 1 > 1 > 1 GΩ
Capacitance @ 1 MHz < 0.8 < 0.8 < 0.8 < 0.8 < 0.8 < 0.8 < 0.8 < 0.8 pF
1)
With test generator 6 kV, 40 Ω
About packing see page 71.
Recommended pad outline
2-Electrode Arresters
2-Elektroden-Ableiter
Comentarios a estos manuales