Light-duty types
1 kA
l
ø 2.8 × 3.5 mm
G31-… G30-…
2.1±0.2
(3.5)
0.5
3.5±0.2
ø2.8±0.2
1
4
3.3
Type
Ordering code
G31-A75X
B88069X
8091B502
G30-A90XSMD
B88069X
9451T203
G31-A90X
B88069X
9361B502
G31-A200X
B88069X
8801B502
B88069X
8801T103
G31-A300X
B88069X2203…
G31-A400X
B88069X
9321B502
G30-A500XSMD
B88069X
2243T203
Nom. DC spark-over voltage V
sdcN
75 90 200 300 400 500 V
Tolerance of V
sdcN
±20 ±20 ±20 ±20 ±20 ±30 %
Impulse spark-over voltage
@ 100 V/µs 99% of
measured values
< 350 < 400 < 750 < 900 < 900 < 1200 V
@ 100 V/µs typical values < 300 < 300 < 500 < 600 < 600 < 1000 V
@ 1 kV/µs 99% of
measured values
< 750 < 700 < 950 < 1200 < 1200 < 1400 V
@ 1 kV/µs typical values < 650 < 600 < 700 < 800 < 850 < 1200 V
Service life
10 operations 8/20 µs 1 1 1 1 1 1 kA
1 operation 8/20 µs 2 2 2 2 2 2 kA
300 operations 8/20 µs 100 100 100 100 100 100 A
200 discharges 1.5 nF; 10 kV; 0 Ω 1.5 ∙ 10
-5
1.5 ∙ 10
-5
1.5 ∙ 10
-5
1.5 ∙ 10
-5
1.5 ∙ 10
-5
1.5 ∙ 10
-5
As
Insulation resistance > 1 > 1 > 1 > 1 > 1 > 1 GΩ
Capacitance @ 1 MHz
< 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 pF