Configuring alarm inputs
76
Siemens Building Technologies
Fire Safety & Security Products 03.2009
Prerequisites
z The SISTORE MX NVS software has been started.
See Section "
1056HStarting SISTORE MX NVS and logging in“, page 1057H17.
z The SISTORE MX NVS software is in configuration mode.
See
362HSection "1058HOpening configuration mode", page 1059H18.
1. Select the Alarm input tab.
2. Select the alarm input you want to configure from the list (
363Hsee 1060HFig. 631061H, page 1062H74).
3. Select a trigger edge in the Trigger edge (global) group field (
364Hsee 1063HFig. 641064H,
page
1065H75).
4. Mark the checkbox level sensitive if relevant (
365Hsee 1066HFig. 651067H, page 1068H75).
5. Click Apply.
Î The setting will be saved.
11.2.2 Priority
The following priorities can be selected for alarm inputs:
z Normal (the alarm input icon in the alarm input list is red, 366Hsee 1069HFig. 631070H, page 1071H74)
z Hold-up (the alarm input icon in the alarm input list is orange)
z Suspicion (only possible if bank mode is active; the alarm input icon in the alarm
input list is purple)
The priority of an alarm input plays a role in the configuration of the recording (
367Hsee
"
1072HConfiguring recording modes", page 1073H122). When an alarm with the priority hold-up
is triggered, active recordings with the normal alarm priority and movement
recordings are automatically ended. However, active recordings with the hold-up
alarm priority cannot be automatically ended.
Fig. 66 Priority group field on the Alarm input tab
Prerequisites
z The SISTORE MX NVS software has been started.
See Section "
1074HStarting SISTORE MX NVS and logging in“, page 1075H17.
z The SISTORE MX NVS software is in configuration mode.
See
368HSection "1076HOpening configuration mode", page 1077H18.
1. Select the Alarm input tab.
2. Select the alarm input you want to configure from the list (
369Hsee 1078HFig. 631079H, page 1080H74).
3. Select the priority of the alarm input in the Priority group field (
370Hsee 1081HFig. 661082H,
page
1083H76).