Configuring alarm outputs
71
Siemens Building Technologies
Fire Safety & Security Products 03.2009
10.3 Event-based or time control of alarm outputs
NOTE:
An alarm output with a special function assigned to it is not available for the configuration of recording.
Fig. 61 Special functions group field on the Alarm output tab
The field selection Normal means no special function (
355Hsee 1031HFig. 611032H, page 1033H71).
Name of the
special function
Function
Remote
controllable
The alarm output can be activated or deactivated by clicking the
status LED icon (in the status display of the switch outputs in
display mode) (
356Hsee 1034HFig. 621035H, page 1036H72). You require the user right
remote control (see Section "
1037HGlobal user rights“, page 1038H92.
Alarm outputs to which the action negative switch impulse or
positive switch impulse have been assigned can also not be
activated or deactivated via the status LED icon.
Error The SISTORE MX sends a signal over the corresponding alarm
output if one of the following faults occurs:
z UPS reports a power failure
z The SISTORE MX NVS software was not properly closed (for
example due to power failure or Watchdog)
z Recording could not be started
z Fatal recording error
z Hard drive full, recording stopped
z Failure of a hard drive
z Windows device driver reports errors (event log)
Alarm SISTORE MX sends a signal over the corresponding alarm output
if an alarm recording is being made. The signal will be sent as long
as the alarm recording lasts.
Motion SISTORE MX sends a signal over the affected alarm output if a
camera has detected a movement. The signal lasts one second. If
the camera detects another movement within this second, the
signal duration will be extended by another second, etc.
Loss of video SISTORE MX sends a signal over the corresponding alarm output
if at least one camera has failed.
Camera
sabotage
SISTORE MX sends a signal over the corresponding alarm output
if camera tampering has been detected.
Recording During recording a signal will be sent periodically via the
corresponding alarm output.