25.13.1 Configuring a monitor as the main monitor
The main monitor displays the operator interface of the application software. The
application software can be configured and operated via this monitor.
IMPORTANT Exactly 1 monitor must be configured as the main monitor.
Fig. 181 Multi-monitor tab – Configuration of the main monitor
Prerequisite:
z The main monitor has not been configured yet.
1. Select the Multi-monitor tab.
2. Mark the checkbox Main monitor.
3. If you want to view events on the main monitor, mark the corresponding
checkboxes and select the duration in seconds.
Option Meaning
Show alarm on monitor for at
least … seconds
Minimum time for which an alarm event will be displayed. New
alarm events will not be displayed during this time.
You can select a time between 0 and 60 seconds. 0 seconds
means that an image will be removed from the screen as soon as
another alarm event occurs.
Show motion alarm on monitor
for at least … seconds
Minimum time for which a motion alarm event will be displayed.
New motion alarm events will not be displayed during this time.
You can select a time between 0 and 60 seconds. 0 seconds
means that an image will be removed from the screen as soon as
another motion alarm event occurs.
Event view window blanked
after … seconds
Period of time after which the event view window will be blanked.
You can select a time between 2 and 300 seconds.
4. Mark the checkboxes of the SISTORE MX NVS servers whose live images are
to be displayed on the main monitor in the Addresses server list.
5. Click Apply.
Î Your settings will be saved.