Operational setup
19
Siemens Building Technologies
Fire Safety & Security Products 03.2009
5.5 SISTORE MX NVS – LAN camera – CKA4810/20
Fig. 6 SISTORE MX NVS – LAN camera – CKA4810/20 system overview
1 CKA4810/20
2 MX NVS server
3 Max. 64 LAN cameras
Prerequisite:
z The CKA driver is installed. Further information on this can be found in the
SISTORE MX NVS Installation Manual.
1. Connect the CKA4810 / 4820 control panel (COM1A port) to the MX NVS server
(COM1/COM2).
2. Configure COM1A on the control panel as an RS232 interface. For more
information please refer to the respective instruction manual for control panel
CKA4810 / CKA4820.
3. Start the SISTORE MX NVS software.
4. Switch to configuration mode.
5. Mark the checkbox Operating console on the System tab.
6. Click Apply.
Î The setting will be saved.
Î The interface for the control panel is now activated.
Connections
Signal MX NVS Server
SISTORE RemoteView
CKA4810 / CKA4820
9-pin Sub-D connector
GND 5 5
RXD 3 2
TXD 2 3
Interface configuration CKA4810 / CKA4820
z Protocol: SIMATRIX RS232 or SIEMENS IVM
z Baud rate: 9600
z Parity: none
Comentarios a estos manuales