Configuring LAN cameras
47
Siemens Building Technologies
Fire Safety & Security Products 03.2009
Adding LAN cameras via the video server
In conjunction with the video servers AXIS 241Q, AXIS 241S and Telscan Web, 4
analog signals can be converted into 4 digital signals. This allows you to configure
4 LAN cameras with the same IP address.
Prerequisite:
z The analog cameras are connected to the video server.
1. Add the LAN cameras as described above.
2. Select the desired video inputs of the analog cameras in the Video input group
field.
3. Click Apply.
Î Your settings will be saved.
7.3 Deleting LAN cameras
Fig. 34 Camera list on the LAN cameras tab
Prerequisites
z The SISTORE MX NVS software has been started.
See Section "
911HStarting SISTORE MX NVS and logging in“, page 912H17.
z The SISTORE MX NVS software is in configuration mode.
See
321HSection "913HOpening configuration mode", page 914H18.
z At least one analog camera is in the camera list. See 322HSection "915HAdding a LAN
camera", page
916H46.
1. Select the LAN cameras tab.
2. Select the camera you want to delete from the camera list (
323Hsee 917HFig. 34918H, page
919H47).
3. Click the Delete button
.
4. Confirm the message that follows with OK.
5. Click Apply.
Î The setting will be saved.