Configuring alarm response
144
Siemens Building Technologies
Fire Safety & Security Products 03.2009
18.3.2 Configuring the ISDN alarm connection
You can configure alarm notification in case of alarms and errors over ISDN.
In case of alarm or error messages, a connection will be made to a SISTORE
RemoteView client and the live image of the particular camera will be shown there.
Prerequisites:
z An ISDN modem is connected to the SISTORE MX NVS server. A driver has
been installed.
z The SISTORE RemoteView application software has been started. See Section
1461H25.2 1462HStarting SISTORE RemoteView and logging in.
z The option Allow alarm connection is enabled in the SISTORE RemoteView
application software. See Section
1463H25.4.2 1464HConfiguring the network connection.
1. Select the Alarm connection tab.
2. Select the Main connection sub-tab.
3. Select the option Connect via ISDN.
4. Mark the checkbox ISDN channel bundling if necessary.
5. Repeat steps 2 and 5 as often as required if you want to set up multiple
connections. You can set up max. 1 main connection and 4 alternative
connections.
Î You can now configure the alarm notification.
Notification in case of alarms
1. Select the Recording tab.
2. Select the Alarm input sub-tab.
3. Mark the checkbox Alarm call
.
In case of an event, the system attempts to call the main recipient via the main connection. If this
does not succeed, a call to the second recipient is made via the first alternative connection, etc.
4. Click Apply.
Î Your settings will be saved.
Notification in case of errors
1. Select the System tab.
2. Mark the checkbox Alarm call
in the Warnings section.
In case of an event, the system attempts to call the main recipient via the main connection. If this
does not succeed, a call to the second recipient is made via the first alternative connection, etc.
3. Click Apply.
Î Your settings will be saved.
Comentarios a estos manuales