Configuring multi-monitor mode
108
Siemens Building Technologies
Fire Safety & Security Products 03.2009
14.4 Configuring a monitor as a sequence monitor
On a sequence monitor, live images can be displayed in an automatic cycle, by
event-based control, or by manual control.
Fig. 95 Multi-monitor tab – Configuration of the sequence monitor
1. Select the Multi-monitor tab.
2. Mark the checkbox Sequence monitor.
3. Mark the corresponding checkboxes and enter the duration in seconds as
necessary:
Option Meaning
Static A camera from the Visible cameras list is fixedly assigned to the
sequence monitor. The live image of no other camera can be
displayed on this monitor.
Manually The fixed assignment of a camera to a monitor (by activating
"Static“) can be changed using the context menu of the live
image in the display mode. A camera can now be activated on
another video output. It is also possible to activate a camera on
one of the four video outputs via SISTORE RemoteView.
Event (alarm or motion) on monitor
at least … seconds
Prerequisite: The checkbox Camera to monitor output on the
Recording tab has been marked. See Section
1263H16.4 1264HConfiguring
recording modes.
If an event occurs, the live image of the selected camera will be
connected to the sequence monitor. This live image will be
displayed at least for the set period of time even if there is an
event on another camera.
PTZ A PTZ camera is connected as soon as it is controlled.
Periodically every… seconds Cameras can be selected from the Visible cameras list and their
images be displayed successively on the sequence monitor. The
selected cameras will be switched in a preset cycle. The dwell
time can be set between 2 and 300 seconds.
Shifting mode Prerequisite: Shifting mode has been configured for 2 sequence
monitors.
The current alarm image is displayed on the first sequence
monitor. This alarm image will be shifted to the second sequence
monitor when another alarm occurs. The new alarm image will be
displayed on the first sequence monitor.
If shifting mode is not activated, the alarm images will be
displayed as the events occur on all sequence monitors
simultaneously.
4. Click Apply.
Î Your settings will be saved.