Configuring multi-monitor mode
105
Siemens Building Technologies
Fire Safety & Security Products 03.2009
14.1 Configuring a monitor as the main monitor
The main monitor displays the operator interface of the application software. The
application software can be configured and operated via this monitor.
IMPORTANT Exactly 1 monitor must be configured as the main monitor.
Fig. 92 Multi-monitor tab – Configuration of the main monitor
Prerequisite:
z The main monitor has not been configured yet.
1. Select the Multi-monitor tab.
2. Mark the checkbox Main monitor.
3. Select the desired view on the main monitor when the application software is
started in the Default screen split list box.
Option Meaning
Auto. matrix The live images of all configured cameras will be displayed.
No display No live images will be displayed until a user logs in.
<Number of cameras> The live images of x cameras will be displayed.
Event view The event view window is opened.
Map The map is opened.
4. If the user is to be able to change the screen split during operation, mark the
checkbox Allow changes by user.
Î The buttons for changing the screen split will be enabled.
5. If the display area is to be shown on the full screen of the main monitor when the
application software is started, mark the checkbox Start in full screen mode.
To exit full screen mode press Esc.
6. If you want to view events on the main monitor, mark the corresponding
checkboxes and select the duration in seconds in the Event window group field:
Option Meaning
Show alarm on monitor for at
least … seconds
Minimum time for which an alarm event will be displayed. New
alarm events will not be displayed during this time.
You can select a time between 0 and 60 seconds. 0 seconds
means that an image will be removed from the screen as soon as
another alarm event occurs.
Show motion alarm on monitor
for at least … seconds
Minimum time for which a motion alarm event will be displayed.
New motion alarm events will not be displayed during this time.
You can select a time between 0 and 60 seconds. 0 seconds
means that an image will be removed from the screen as soon as
another motion alarm event occurs.
Event view window blanked
after … seconds
Period of time after which the event view window will be blanked.
You can select a time between 2 and 300 seconds.