Configuring multi-monitor mode
107
Siemens Building Technologies
Fire Safety & Security Products 03.2009
14.3 Configuring a monitor as an event monitor
The event monitor displays events. An event can be either a movement or an
alarm.
When an event monitor has been configured, it is no longer possible to display events on the main
monitor.
Fig. 94 Multi-monitor tab – Configuration of the event monitor
1. Select the Multi-monitor tab.
2. Mark the checkbox Event monitor.
3. Mark the corresponding checkboxes and enter the duration in seconds in the
Event monitor group field:
Option Meaning
Show alarm on monitor for at
least … seconds
Minimum time for which an alarm event will be displayed. New
alarm events will not be displayed during this time.
You can select a time between 0 and 60 seconds. 0 seconds
means that an image will be removed from the screen as soon as
another alarm event occurs.
Show motion alarm on monitor
for at least … seconds
Minimum time for which a motion alarm event will be displayed.
New motion alarm events will not be displayed during this time.
You can select a time between 0 and 60 seconds. 0 seconds
means that an image will be removed from the screen as soon as
another motion alarm event occurs.
Event view window blanked
after … seconds
Period of time after which the event view window will be blanked.
You can select a time between 2 and 300 seconds.
4. Select the cameras whose event images are to be displayed on the event
monitor by marking the corresponding checkboxes in the Visible cameras list
(see
1262HFig. 91).
5. Click Apply.
Î Your settings will be saved.