Network configuration
35
Siemens Building Technologies
Fire Safety & Security Products 03.2009
6.2 Configuring the network connection
NOTE:
If you operate the SISTORE MX NVS software or SISTORE RemoteView behind a firewall and want
to access via a network, open all ports in the firewall that are used by the software.
All users logged in to the SISTORE MX NVS software (locally or via SISTORE
RemoteView) can simultaneously view live images or recordings and alarm
outputs.
All connections between the SISTORE MX NVS software and users logged in via
SISTORE RemoteView will be terminated automatically when the following events
occur:
z The configuration of the SISTORE MX NVS software is overwritten.
z Configuration mode is started in the SISTORE MX NVS software.
Fig. 20 TCP/IP parameters group on the Network tab
Prerequisites
z The network has been set up in the operating system and is ready for use.
z The SISTORE MX NVS software has been started.
See Section "
825HStarting SISTORE MX NVS and logging in“, page 826H17.
z The SISTORE MX NVS software is in configuration mode.
See
297HSection "827HOpening configuration mode", page 828H18.
1. Select the Network tab.
2. Mark the checkbox Allow network access (
298Hsee 829HFig. 20830H, page 831H35).
Î The TCP/IP parameters group will be activated.
3. Confirm the message that follows with OK.
4. In the TCP/IP Port field, enter the number of the port to be used by the
SISTORE RemoteView clients for connecting to the SISTORE MX NVS
software.
5. In the Max. clients field, select the maximum number of SISTORE RemoteView
clients that are permitted to connect simultaneously to the SISTORE MX NVS
software.
6. Enter the initial value of the TCP/IP port range in the field for TCP/IP port range.
Î The end value of the TCP/IP port range is determined automatically. It
depends on the max. clients value: two ports are needed for each client.
7. Click OK.