25.4.2 Configuring the network connection
If you operate the SISTORE MX NVS application software or SISTORE RemoteView behind a firewall
and want to access via a network, open all ports in the firewall that are used by the software.
Fig. 165 SISTORE RemoteView – Network tab
Prerequisite:
z The SISTORE MX NVS server is connected to the network.
1. Select the Network tab.
2. Mark the checkbox Allow alarm connection.
3. Confirm the message that follows with OK.
4. In the TCP/IP port field, enter the number of the port at which the
SISTORE RemoteView application software can be reached. Typically port 41 is
used.
5. Enter the initial value of the TCP/IP port range in the field for TCP/IP port range.
6. The end value of the TCP/IP port range is determined automatically. It depends
on the max. clients value: two ports are needed for each client.