Configuring alarm outputs
72
Siemens Building Technologies
Fire Safety & Security Products 03.2009
Time control The SISTORE MX sends a signal over the corresponding alarm
output at the specified times.
If you select this special function the Options… button will be
enabled.
1. Click Options...
Î The SISTORE MX NVS Time control window will open.
2. Configure the time table. See
357HSection "1039HConfiguring time control",
page
1040H77.
Î The SISTORE MX NVS will send a signal over the alarm output
during the marked (blue) time segments.
3. Click OK.
Î The dialog will close.
4. Click Apply.
Î Your settings will be saved.
Remote
connection
The alarm output will be activated as soon as there is at least one
connection to a SISTORE RemoteView client.
Tab. 3 Special functions of the alarm outputs
Fig. 62 Status of all alarm outputs in display mode
1
The special function remote controllable is assigned to the alarm output, and it is
deactivated.
2
The special function remote controllable is assigned to the alarm output, and it is
activated.
3
The special function remote controllable is not assigned to the alarm output, but
the output is configured.
4
The alarm output is not configured.
The status display of the alarm outputs is also shown in SISTORE RemoteView.
The status LED icons represent the alarm outputs in sequence (1 to 16) from the
top left to the bottom right.
Event-controlled alarm output activation/deactivation
Prerequisites
z The SISTORE MX NVS software has been started.
See Section "
1041HStarting SISTORE MX NVS and logging in“, page 1042H17.
z The SISTORE MX NVS software is in configuration mode.
See
358HSection "1043HOpening configuration mode", page 1044H18.
1. Select the Alarm output tab.
2. Select a special function from the Special functions dropdown list (
359Hsee 1045HFig. 611046H,
page
1047H71).
3. If you have selected the time control special function: see the table Special
functions of the alarm outputs under the entry time control.
4. Click Apply.
Î Your settings will be saved.
Vista de pagina 71