Cycle alarms
06/2009 Overview of alarms
2-273
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62501 [Channel %1: ] Block %2: Speed has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy: Check speed and program a lower value in the NC program if necessary
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62502 [Channel %1: ] Block %2: Dresser %4, GWPS has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy: Check limit value for GWPS and program a lower value in the NC program if necessary
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62503 [Channel %1: ] Block %2: Dresser %4, speed has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy: Check speed and program a lower value in the NC program if necessary
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62900 [Channel %1: ] Block %2: Incorrect source file
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62901 [Channel %1: ] Block %2: Source file not available
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62902 [Channel %1: ] Block %2: Not yet implemented
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62903 [Channel %1: ] Block %2: Incorrect contour
Parameters: %1 = Channel number
%2 = Block number, label channel number
Vista de pagina 272