Siemens SINUMERIK 802D sl Manual del operador Pagina 231

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 340
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 230
Cycle alarms
06/2009 Overview of alarms
2-231
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61301 [Channel %1: ] Block %2: Probe not switching
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The measuring distance was completely traversed but no switching signal was generated at the mea-
suring input.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: -Check measuring input.
-Check measuring distance.
-Probe defective.
61302 [Channel %1: ] Block %2: Probe - collision
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The measuring probe collided with an obstacle when being positioned.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: ? Check spigot diameter (may be too small)
? Check measuring distance (may be to long)
61303 [Channel %1: ] Block %2: Safety margin exceeded
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The measuring result differs greatly from the specified value.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: -Check setpoint value.
-Increase parameter _TSA.
61304 [Channel %1: ] Block %2: Allowance
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61305 [Channel %1: ] Block %2: Dimension too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Vista de pagina 230
1 2 ... 226 227 228 229 230 231 232 233 234 235 236 ... 339 340

Comentarios a estos manuales

Sin comentarios