Cycle alarms
06/2009 Overview of alarms
2-259
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61740 [Channel %1: ] Block %2: Blank must be closed contour
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE950.
Remedy: Check whether blank contour is closed, i.e. starting point = end point.
61741 [Channel %1: ] Block %2: Cancel due to insufficient memory space
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE950.
Remedy: --
61742 [Channel %1: ] Block %2: Approach collision, correction not possible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE950.
Remedy: --
61766 [Channel %1: ] Block %2: Error in blank program
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61798 [Channel %1: ] Block %2: Acknowledgment error ACTIVATE
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61799 [Channel %1: ] Block %2: Acknowledgment error READYPROG
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Comentarios a estos manuales