Siemens SINUMERIK 802D sl Manual del operador Pagina 227

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 340
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 226
Cycle alarms
06/2009 Overview of alarms
2-227
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61271 [Channel %1: ] Block %2: Chamfer width > tool radius
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Chamfer width larger than tool radius.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Use a larger tool.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61272 [Channel %1: ] Block %2: Insertion depth too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Insertion depth on chamfering too small.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase the insertion depth.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61273 [Channel %1: ] Block %2: Insertion depth too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Insertion depth on chamfering too large.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Decrease the insertion depth.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61274 [Channel %1: ] Block %2: Invalid tool angle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Invalid tool angle.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check tool angle.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61275 [Channel %1: ] Block %2: Target point violates software limit switch!
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Due to a swivel action, the end point is outside the software limit switches.
Vista de pagina 226
1 2 ... 222 223 224 225 226 227 228 229 230 231 232 ... 339 340

Comentarios a estos manuales

Sin comentarios