Overview of alarms 06/2009
NCK alarms
2-24
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions: In the specified machine data, a number has been specified for the configuration of an M function
which is occupied by the system, and cannot be used for an assignment. (M0 to M5, M17, M30, M40
to M45 and also M98, M99 with applied ISO dialect). The value set by the user has been reset to the
default value by the system.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure an M function in the specified machine data which is not occupied by the system (M0 to M5,
M17, M30, M40 to M45 and also M98, M99 with applied ISO dialect).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4183 [Channel %1: ] M auxiliary function number %2 used several times (%3
and %4)
Parameters: %1 = Channel number
%2 = M auxiliary function number
%3 = MD identifier
%4 = MD identifier
Definitions: In the specified machine data, a number has been used several times for the configuration of an M
function.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Check the specified machine data and create a unique assignment of M auxiliary function numbers.
Program Con-
tinuation:
Switch control OFF - ON.
4184 [Channel %1: ] Illegally predefined auxiliary function in %2%3, MD reset
Parameters: %1 = Channel number
%2 = MD identifier
%3 = If required, MD index
Definitions: In the specified machine data, a predefined auxiliary function has been illegally configured.
The value set by the user has been reset to the default value by the system.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure a valid value in the specified machine data.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4185 [Channel %1: ] Illegal auxiliary function configured %2 %3 %4
Parameters: %1 = Channel number
%2 = Type of auxiliary function
%3 = Extension
%4 = Auxiliary function value
Definitions: An auxiliary function has been illegally configured.
Predefined auxiliary functions cannot be reconfigured by user-defined auxiliary functions.
See:
MD22010 $MC_AUXFU_ASSIGN_TYPE[n]
MD22020 $MC_AUXFU_ASSIGN_EXTENSION[n]
MD22030 $MC_AUXFU_ASSIGN_VALUE[n]