Overview of alarms 06/2009
Cycle alarms
2-238
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61354 [Channel %1: ] Block %2: File for logfile not found
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
No name specified for the log file.
Remedy: Check parameter _PROTNAME[1].
61355 [Channel %1: ] Block %2: Incorrect file type for logfile
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The file extension for the log file is incorrect.
Remedy: Check parameter _PROTNAME[1].
61356 [Channel %1: ] Block %2: File for logfile is being used
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The log file is already used by an NC program.
Remedy: Check parameter _PROTNAME[1].
61357 [Channel %1: ] Block %2: No resources free
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
Not enough NC memory space available.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Delete the files.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61358 [Channel %1: ] Block %2: Error during recording
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
Internal error
Remedy: Call the hotline!
61359 [Channel %1: ] Block %2: - continue with RESET
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
Internal error
Remedy: Call the hotline!
61360 [Channel %1: ] Block %2: Log job undefined - continue with RESET
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycle: CYCLE106.
Cycle CYCLE106 was called by an incorrect parameter.
Remedy: Check cycle call for CYCLE106, specifically the call parameter.
61361 [Channel %1: ] Block %2: Variable cannot be recorded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105.
The value specified in _PROTVAL[] cannot be logged.
Comentarios a estos manuales