Overview of alarms 06/2009
NCK alarms
2-160
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
%3 = Axis name, spindle number
Definitions: An axis is to travel in JOG with revolutional feed, but the spindle/axis the feed is to be derived from is 0.
Reaction: Alarm display.
Remedy: Traverse the spindle/axis from which the feed is to be derived.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
20057 [Channel %1: ] Block %2 revolutional feedrate for axis/spindle %3 is <=
zero
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions: Revolutional feed has been programmed for an axis/spindle, but the velocity was not programmed or
the programmed value is smaller than or equal to zero.
Reaction: Correction block is reorganized.
Local alarm reaction.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
- Correct the part program or
- Specify the correct feed for PLC axes at the VDI interface,
- Specify feed for oscillating axes in the SD43740 $SA_OSCILL_VELO.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
20058 [Channel %1: ] Axis %2 revolutional feedrate: illegal feed source
Parameters: %1 = Channel number
%2 = Axis name, spindle number
Definitions: An axis/spindle is to be traversed at revolutional feedrate. The reference axis/spindle defined in SD
43300 $SA_ASSIGN_FEED_PER_REV_SOURCE refers to itself. The coupling caused cannot be
executed.
Reaction: Alarm display.
Remedy: The reference axis/spindle must be modified accordingly in SD 43300.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
20060 [Channel %1: ] Axis %2 cannot be traversed as geometry axis
Parameters: %1 = Channel number
%2 = Axis name
Definitions: The axis is currently not in "Geometry axis" state. Therefore, it cannot be traversed in JOG mode as
geometry axis.
If the abbreviation WCS (workpiece coordinate system) is displayed in the "Position" screen, then only
the geometry axes can be traversed by means of the direction keys! (MCS ... Machine coordinate
system; all machine axes can now be traversed by using the direction keys on the machine control
panel).
Reaction: Alarm display.
Remedy: Check the operating steps to establish whether geometry axes really must be traversed, otherwise
switch over to the machine axes by activating the "WCS/MCS" key on the machine control panel.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
20062 [Channel %1: ] Axis %2 already active
Parameters: %1 = Channel number
%2 = Axis name, spindle number
Definitions: The displayed axis is already traversing as a machine axis. Therefore, it cannot be operated as a
geometry axis.
Traversing an axis can take place in JOG mode through 2 different interfaces.
Vista de pagina 159