Siemens SINUMERIK 802D sl Manual del operador Pagina 222

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 340
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 221
Overview of alarms 06/2009
Cycle alarms
2-222
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: Increase infeed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61249 [Channel %1: ] Block %2: Number of edges too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The number of edges is too small.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase number of edges.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61250 [Channel %1: ] Block %2: Width across flats/edge length too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The width across flats/edge length is too small.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase key width/edge length.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61251 [Channel %1: ] Block %2: Width across flats/edge length too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The width across flats/edge length is too large.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Decrease key width/edge length.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61252 [Channel %1: ] Block %2: Chamfer/radius too large
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Chamfer/radius is too large.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Decrease chamfer/radius.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61253 [Channel %1: ] Block %2: No finishing allowance programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No finishing allowance has been entered.
Vista de pagina 221
1 2 ... 217 218 219 220 221 222 223 224 225 226 227 ... 339 340

Comentarios a estos manuales

Sin comentarios