Overview of alarms 06/2009
Cycle alarms
2-232
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61306 [Channel %1: ] Block %2: Permissible measuring difference exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: CYCLE971, CYCLE972, CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE982, CYCLE994.
Remedy: -Check setpoint value
-Increase parameter _TDIF
61307 [Channel %1: ] Block %2: Incorrect measuring variant
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: The value of parameter _MVAR is impermissible.
61308 [Channel %1: ] Block %2: Check measuring path _FA
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: A traversing path for measuring was generated whose size was specified by parameter _FA that
describes the maximum distance before and after the switching position (workpiece edge) and that
must have a value greater than 0.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: Check parameter _FA.
61309 [Channel %1: ] Block %2: Check probe type
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Probe type: 3D probe inactive.
This alarm is generated by all cycles except for CYCLE971, CYCLE972, CYCLE982.
Remedy: The probe has to be of the "3D probe" type in the tool management.
Tool type of the workpiece probe in the TO memory is impermissible.
For CYCLE971: no permissible tool probe type entered in _TP[x,8], or check
the permissible working plane G17...G19 for tool type "Wheel".
61310 [Channel %1: ] Block %2: Scale factor is active
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Scale factor = scaling is active.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: Switch off the active scale factor in the program. Measuring is not possible with an active scale factor.
61311 [Channel %1: ] Block %2: No D number active
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No tool offset for the measuring probe (for workpiece measurement) or no tool offset for the active tool
(for tool measurement) is selected.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: Select the tool's tool edge number D.
61312 [Channel %1: ] Block %2: Check measuring cycle number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy: Measuring cycle called is impermissible...
61313 [Channel %1: ] Block %2: Check probe number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The probe has an impermissible value (_PRNUM).
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy: Correct _PRNUM or create data field _TP[] or _WP[] for additional tool or workpiece probe