Page 194 HydroRanger 200 – INSTRUCTION MANUAL 7ML19981FC01
mmmmm
Parameters
P818 Profile Pointer Distance
The distance between the transducer face and the Profile Pointer.
P819 Profile Pointer Amplitude
The amplitude (in dB above 1 uV) of the Echo Profile at the Pointer position.
P820 Algorithm
Chooses the algorithm to generate the measured value from the profile.
Primary Index Global
Values Range: 0.000 to 9999 (view only)
Related
• P817 Profile Pointer Time
• P819 Profile Pointer
Amplitude
• P820 Algorithm
• P821 Spike Filter
• P822 Narrow Echo Filter
• P823 Reform Echo
• P825 Echo Marker Trigger
Primary Index Global
Values Range: 00 to 99 (view only)
Related
• P817 Profile Pointer Time
• P818 Profile Pointer
Distance
• P820 Algorithm
• P821 Spike Filter
• P822 Narrow Echo Filter
• P823 Reform Echo
• P825 Echo Marker Trigger
Primary Index Global
Values
1 ALF = flat Area, Largest, and First average
2 A = flat Area only
3 L = flat Largest only
4 F = flat First only
5 AL = flat Area and Largest average
6 AF = flat Area and First average
7 LF = flat Largest and First average
8 * bLF = smooth Largest or First
9 bL = smooth Largest only
10 bF = smooth First only