
Index-8
Ladder Logic (LAD) for S7-300 and S7-400
C79000-G7076-C504-02
POS. See Address Positive Edge Detection
instruction
Positive RLO Edge Detection ––(P)––
instruction, 8-19
Power flow, inverting, 8-7
Program control instructions
Call FC/SFC from Coil ––(CALL),
20-2–20-3
Master Control Relay Off ––(MCR>),
20-12–20-13
Master Control Relay On ––(MCR<),
20-12–20-13
Return ––(RET), 20-7
Program status, 5-5
See also Test
selecting the call environment, 5-7
settings, 5-6
starting and stopping, 5-8
Programming, practical applications, B-2–B-16
Programming language, selection, 2-5
Pulse S5 Timer (S_PULSE), 9-5–9-6
Pulse Timer Coil ––(SP) instruction, 8-14–8-15
R
Real number
comparing two real numbers, 13-5–13-6
data type, 7-3, C-3
format, C-4–C-6
range, 7-3, C-3
Reinitialize, an actual value, 4-7
Reinitializing, 4-7
Repetition factor, 3-9
Reset Coil ––(R) instruction, 8-10
Reset Set Flipflop (RS) instruction, 8-24–8-25
Result Bit instructions, 19-4–19-5
Result of logic operation (RLO)
inverting, 8-7
negating, 8-7
Retentive On-Delay S5 Timer (S_ODTS),
9-11–9-12
Retentive On-Delay Timer Coil ––(SS)
instruction, 8-17
Return ––(RET) instruction, 20-7
Return Fraction Double Integer (MOD_DI)
math instruction, 11-10–11-11
ROL_DW. See Rotate Left Double Word
instruction
ROR_DW. See Rotate Right Double Word
instruction
Rotate instructions, 16-10–16-13
Rotate Left Double Word (ROL_DW),
16-10–16-11
Rotate Right Double Word (ROR_DW),
16-11–16-12
Rotate Left Double Word (ROL_DW)
instruction, 16-10–16-11
Rotate Right Double Word (ROR_DW)
instruction, 16-11–16-12
ROUND. See Round to Double Integer
conversion instruction
Round to Double Integer (ROUND) conversion
instruction, 14-15–14-16
RS. See Reset Set Flipflop instruction
Rules, Ladder, 3-15
S
S_AVERZ. See Off–Delay S5 Timer instruction,
SIMATIC short name
S_CD. See see Down Counter instruction
S_CU. See see Up Counter instruction
S_CUD. See Up-Down Counter instruction
S_EVERZ. See On–Delay S5 Timer instruction,
SIMATIC short name
S_IMPULS. See Pulse S5 Timer instruction,
SIMATIC short name
S_ODT. See On-Delay S5 Timer instruction
S_ODTS. See Retentive On-Delay S5 Timer
instruction
S_OFFDT. See Off-Delay S5 Timer instruction
S_PEXT. See Extended Pulse S5 Timer
instruction
S_PULSE. See Pulse S5 Timer instruction
S_SEVERZ. See Retentive On-Delay S5 Timer
instruction, SIMATIC short name
S_VIMP. See Extended Pulse S5 Timer
instruction, SIMATIC short name
S5 TIME
format, C-9
range, 7-3, C-3
time base, 9-2–9-3, C-9
time value, 9-2
Save RLO to BR Memory ––(SAVE)
instruction, 8-8
Saving blocks, 2-6
Scan time, 5-9
Selecting
in networks, 3-18
Ladder instructions, 3-18
Index
Comentarios a estos manuales