Siemens NAN 67 Series Manual de servicio Pagina 105

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 318
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 104
8-7
Ladder Logic (LAD) for S7-300 and S7-400
C79000-G7076-C504-02
8.6 Invert Power Flow
The Invert Power Flow instruction negates the RLO.
Table 8-5 Invert Power Flow Element
LAD Element Parameter Data Type Memory Area Description
NOT
None
Status Word Bits
BR CC 1 CC 0 OV OS OR STA RLO FC
Write 1 *
I 0.0
I 0.1 I 0.2
Q 4.0
Output Q 4.0 is 1 if one of the following
conditions exists:
S The signal state at input I 0.0 is NOT 1
S Or the signal state is NOT 1 at either
input I 0.1 or input I 0.2 or both.
NOT
Figure 8-5 Invert Power Flow
Description
Bit Logic Instructions
Vista de pagina 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 317 318

Comentarios a estos manuales

Sin comentarios