IP 240 Error Messages
Table 14-7. Data Errors in Positioning Mode (Continued)
Chan. 1
Description
Exten-
sion
Chan. 2
Error code for
60 90 nn Position number specified together with control bit HAND
=specified position numbernn
61 91 nn Invalid combination of control bits FREI, HAND, DA1S
and DA2S.
nn =00 Control bits DA1S and DA2S in conjunction with
HAND=1 illegal for configuring parameter DAV
=02 HAND=1 and FREI=1 transferred for reference point
approach or direction of travel not correctly specified
via DA1S or DA2S and DAV=2
62 92 nn Contents of data block or transfer buffer invalid
Check contents and enter "0" in all unused positions
=00 Error while transferring zero offset
=01 Error while transferring control bits
=02 Error while transferring position values
=03 Error while transferring distance values
=04 Error while transferring position 0
nn
63 93 Illegal value specified as BCD number.nn
=01 Error in position value transferred
=02 Error in distance value transferred
=03 Error in zero offset transferred
=04 Error in final value for rotary axis
nn
nn Certain control bits and data can be specified only when
IP outputs are reset.
Check the states of the IP outputs
64 94
=00 Error when selecting a position from 1 to 254
=01 Error on transferring zero offset
=02 Error on selecting HASY
=04 Error on selecting HAND
=05 Error on transferring position values
=06 Error on transferring distance values
nn