Siemens IP-Module Especificaciones Pagina 144

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 417
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 143
IP 240 Counting
DB14 LEN=43
0: KH = 0000;
1: KS =' '; MACHINE-READABLE PRODUCT CODE OF THE MODULE
4: S =' '; FIRMWARE VERSION
7: KS =' '; HARDWARE VERSION
8: KH = 0000; ERROR FLAGS FOR
9: KH = 0000; HARDWARE AND
10: KH = 0000; COMMUNICATIONS ERRORS
11: KH = 8001;
12: KH = 0000;
13: KH = 0000; PAFE BITS
14: KH = 0001;
15: KH = 0000;
16: KH = 0008;
17: KM = 0000000100010000; CONTROL BITS
18: KM = 0000000000100000; STATUS BITS
19: KM = 0000000000000000; STATUS BITS
20: KM = 0000000000000000; INTERRUPT REQUEST BYTES CHANNEL1
21: KM = 0000000000000000; INTERRUPT REQUEST BYTES CHANNEL2
22: KH = 0000;
23: KY = 002,014; MODE AND DB NUMBER
24: KH = 0000;
25: KH = 0000;
26: KH = 0000;
27: KH = 0000;
28: KH = 0000;
29: KH = 0000;
30: KH = 0000; ACTUAL VALUE IN BCD CODE
31: KH = 0030;
32: KM = 0000000000000000; ACTUAL VALUE IN BINARY CODE
33: KM = 0000000000011110;
34: KH = 0000; INITIAL COUNT VALUE
35: KH = 0040;
36: KS ='END'; FREE FOR USER FROM DW36 ON
38:
EWA 4NEB 811 6120-02a
8-19