Counting IP 240
Technical Specifications
Block number : 171
Block name : STRU. DOS
PLC Library number
Call length/
Block length
CPU Processing time
1
S5-115U P71200-S 5171-D-2 9 words/
814 words
941-7UA...
942-7UA...
943-7UA...
944-7UA...
approx. 72 ms
approx. 46 ms
approx. 30 ms
approx. 13 ms
941-7UB...
942-7UB...
943-7UB...
944-7UB...
approx. 27 ms
approx. 11.5
S5-135U/
S5-135U
P71200-S 9171-D-2 10 words/
1248 words
922 from A9
928-3UA...
approx. 25 ms
approx. 18 ms
928-3UB... approx. 11 ms
S5-150U P71200-S 4171-D-1 11 words/
1256 words
approx. 12 ms
S5-155U P71200-S 6171-B-1 11 words/
1302 words
946-3UA.../
947-3UA...
approx. 11 ms
Nesting depth : 0
Subordinate blocks : none
Assignments in data area : data block specified with DBNR parameter up to and
including DW 35
Assignments in flag area : MB 240 to 255
System statements : yes
1
The specified processing times are for an FB call following an IP 240 firmware cycle without data interchange.