Series commissioning and operation
8.2 Series commissioning and replacement of the frequency converter
ET 200pro FC
134 Operating Instructions, 11/2007, A5E01100763B AA
8.2.2 Series commissioning
Overview
The term series commissioning refers to the process of transferring the parameter set from
one frequency converter to a number of other frequency converters in order to carry out
quick commissioning of identical applications (e.g. series machines or groups of converters).
Series commissioning is divided into the following steps:
● Creating a valid parameter set
● Uploading this parameter set
● Downloading the uploaded parameter set to the new frequency converter
The precondition for carrying out series commissioning is that there must be a suitable
parameter set available. This parameter set can be created by using the STARTER software
for frequency converter parameterization.
CAUTION
Downloading parameters between different firmware versions can lead to incorrect
parameter settings.
The LEDs should flash when parameters are downloaded from an MMC to the frequency
converter's EEPROM (e.g. during series commissioning). The parameters must be checked
after a download.
As soon as you have a frequency converter with a suitable parameter, you can upload the
parameter set. The next step is then to download it to the new frequency converter using the
STARTER software or MMC.
86656
67$57(5
0LFUR
0HPRU\
&DUG
67$57(5
$Q00&DVSDUDPHWHUPHPRU\
LVHVVHQWLDOIRUWKHFRQQHFWLRQ
56LQWHUIDFHFDEOHRSWLFDO
352),%86RU352),1(7WKURXJK,0
Figure 8-1 Series commissioning interfaces