Series commissioning and operation
8.1 Transfer of the frequency converter parameter assignment
ET 200pro FC
Operating Instructions, 11/2007, A5E01100763B AA
125
8.1.2 Parameter transfer - Terms
Upload
"Upload" refers to the transfer of parameters from the internal memory to an external storage
medium (e.g., MMC).
Download
"Download" refers to the transfer of parameters from an external storage medium to the
frequency converter's internal memory.
Supplementary conditions
The following supplementary conditions must be observed in respect of uploads/downloads:
Once the upload/download procedure is under way, there is no way of stopping it again.
If the data being downloaded are incompatible with the frequency converter, the relevant
parameters in the converter will revert to their default values.
All the LEDs will flash during the upload/download process. On successful completion of
the process, the "RY/RDY" LED will light up.
CAUTION
Downloading parameters between different frequency converters or firmware versions is
not recommended.
It is possible to download parameter sets between different frequency converters, but
the user bears full responsibility for the consistency of the downloaded parameter set,
as the sets may differ from one another.