Configuration
68
Siemens Building Technologies
Fire Safety & Security Products 12.2008
NOTE
You can change the settings of relay alarm output in the No. 1.
Each alarm output can be given its own title by highlighting the box under the Title
heading and pressing the
button. A virtual keyboard appears allowing you to
enter the title.
Highlighting the boxes under the Type heading allows to set the alarm output for
NO or NC (normally open or normally closed).
Highlighting the box beside Dwell Time and pressing the
button allow you to set
the dwell time of the alarm output. Dwell times range from 5 seconds to 15
minutes.
Highlighting the Schedule tab causes the Schedule screen to display.
Fig. 80 Alarm-Out Schedule screen
You can add and edit alarm output schedules on this screen. Highlight the "+" and
press the
button to add a schedule. Highlighting the boxes under the column
heading and pressing the
button allow you to edit the information in those
boxes.
The Day box allows you to select the days that the alarm schedule will be active.
The choices are: Sun, Mon, Tue, Wed, Thu, Fri, Sat, M~F, Hol and All.
The Range box allows you to set the time that the alarm schedule will be active in
15-minute increments from 00:00 to 24:00.
The Mode box allows you to set how the alarm reacts during the scheduled time.
When set to On, the Alarm-Out is active during the scheduled time. When set to
Event, the Alarm-Out is only active when there is an Event during the scheduled
time.
The Channels box allows you to set which alarm outputs will be active. You can
also select the DVR’s internal buzzer.
The
box allows you to delete an alarm output schedule. You will be asked to
confirm whether or not you really wish to delete the schedule.
Î You can save your Alarm-Out changes by highlighting Save and pressing the
button.
Î Selecting Cancel exits the screen without saving the changes.