Configuration
58
Siemens Building Technologies
Fire Safety & Security Products 12.2008
3. Highlight the Storage tab and the Storage screen displays.
Fig. 65 Storage screen
Storage
1. Highlight the box beside Disk Bad Notify, and press the
button.
2. Select percentage level of bad disk sectors at which you want the DVR to
trigger an alert. Percentage levels range from 10% to 90%.
3. Highlight the box beside Disk Almost Full Notify, and press the
button.
4. Select the percentage level of disk usage at which you want the DVR to
trigger an alert. Percentage levels range from 80% to 99%.
5. Highlight the first box beside Disk S.M.A.R.T., and press the
button.
6. Use the Up and Down arrow buttons to scroll through the numbers. Refer to
the hard disk drive manufacturer’s documentation for the correct temperature
setting.
Î If the temperature of hard disk drive exceeds the defined threshold, the
system triggers an alert.
7. Highlight the second box beside Disk S.M.A.R.T., and press the
button.
8. Select either ºC (Celsius) or ºF (Fahrenheit), and press the
button.
9. Highlight OK, and press the
button to accept the changes.
Î Selecting Cancel exits the screen without saving the changes.
10. Highlight the Actions tab.
Î The System Event - Actions screen displays.
Fig. 66 System Event - Actions screen