Configuring with Web Based Management
5.3 "Wizard" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
55
The page contains the following boxes:
●
"Telnet Server" check box
Enable or disable the "Telnet Server" service for unencrypted access to the CLI.
●
Enable or disable the "SSH Server" service for encrypted access to the CLI.
●
"HTTPS Server only" check box
Enable or disable access using HTTPS.
●
drop-down list
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
– "-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
– Read/Write
With DCP, device parameters can be both read and modified.
– Read-Only
With DCP, device parameters can be read but cannot be modified.
●
Select the protocol from the drop-down list. The following settings are possible:
– "-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
– SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
– SNMPv3
Access to device parameters is possible with SNMP version 3. You can configure
other settings in "System > SNMP > General".
●
check box
Enable or disable write access to SNMP variables with SNMPv1/v2c.
● "
SINEMA Configuration Interface
" check box
If the SINEMA configuration interface is enabled, you can download configurations to the
device via the TIA Portal.