Siemens IEEE802.11 Instrucciones de operaciones Pagina 254

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 253
Configuring with Web Based Management
5.9 "Security" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
254 Configuration Manual, 11/2014, C79000-G8976-C323-03
5.9.2.3
AP Radius Authenticator
Configuration of the RADIUS server
On this page, you define the RADIUS servers and the RADIUS authentication of the access
point. You can enter data for two RADIUS servers.
Note
This ta
b is available only in access point mode.
Description
The page contains the following boxes:
Reauthentication Mode
Specify who sets the time after which the clients are forced to reauthenticate.
Disabled
Reauthentication mode is disabled.
Server
Enables time management on the server.
Local
Enables local time management. In "Reauthentication Interval", specify the time of
validity.
Reauthentication Interval [s]
If time management is local, enter the period of validity of the authentication in seconds.
The minimum time is 1 minute (enter 60), the maximum time is 12 hours (enter 43200).
The default is one hour (3,600 seconds).
The table has the following columns:
Server IP Address
Here, enter the IP address or the FQDN name of the RADIUS server.
Server Port
Enter the input port on the RADIUS server.
Shared Secret
Enter the password of the RADIUS server.
For the password, ASCII code 0x20 to 0x7e is used.