Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
194 Configuration Manual, 11/2014, C79000-G8976-C323-03
"Mode Type" drop-down list
Note
This parameter cannot be configured for the SCALANCE W770/W730 devices. The value
is preset to "Autonegotiation" for both ports.
Mode
Shows the transmission speed and the transmission method of the port.
Negotiation
Shows whether the automatic configuration of the connection to the partner port is
enabled or disabled.
"MTU" input box
Enter the packet size above which packets are fragmented.
Link
Shows the connection status to the network. The available options are as follows:
Up
The port has a valid link to the network, a link integrity signal is being received.
Down
The link is down, for example because the connected device is turned off.
Changing the port configuration
Click the appropriate box to change the configuration.
Note
With various automatic functions, the
device prevents or reduces the effect on other ports
and priority classes (Class of Service) if a port is overloaded. This can mean that frames are
discarded even when flow control is enabled.
Port overload occurs when the device receives more frames than it can send, for example as
the result of different transmission speeds.
Procedure
Follow the steps below to change the settings:
1. Change the settings according to your configuration.
2. Click the "Set Values" button.