Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
161
The table has the following columns:
Select
Select the row you want to delete.
Group Name
Shows the defined group names.
Security Level
Shows the configured security level.
Read
Enable or disable read access for the required group.
Write
Enable or disable wite access for the required group.
Note
For write access to work, you also need to enable read access.
Persistence
Shows whether or not the group is assigned to an SNMPv3 user. If the group is not
assigned to an SNMPv3 user, no automatic saving is triggered and the configured group
disappears again after restarting the device.
Yes
The group is assigned to an SNMPV3 user.
No
The group is not assigned to an SNMPV3 user.
Procedure
Creating a new group
1. Enter the required group name in "Group Name".
2. Select the required security level from the "Security Level" drop-down list.
3. Click the "Create" button to create a new entry.
4. Specify the required read rights for the group in " Read".
5. Specify the required write rights for the group in " Write".
6. Click the "Set Values" button.