Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
159
Traps
SNMP traps for alarm events
If an alarm event occurs, a device can send SNMP traps (alarm frames) to up to ten different
management stations at the same time. Traps are only sent if the events specified in the
"Events" menu occur.
Note
Traps are sent only when the "SNMPv1 Traps" option was selected in the "General" or
"System >
Confguration" tab.
●
Enter the IP address or the FQDN name of the station to which the device sends SNMP
traps. You can specify up to ten different recipients servers.
The table has the following columns:
●
Select the row you want to delete.
●
If necessary, change the IP addresses or the FQDN names of the stations.
●
Enable or disable the sending of traps. Stations that are entered but not selected do not
receive SNMP traps.
Procedure
Creating a trap entry
1. In "IP Address", enter the IP address or the FQDN name of the station to which the
device sends traps.
2. Click the "Create" button to create a new trap entry.
Comentarios a estos manuales